Died HOUSE · SESSION 2026

No. HB 553

Temporary Door Locking Devices
Send via email
SPONSOR
Partington
FILED BY
Bill Partington — District 28, Republican [search donations]
EFFECTIVE
7/1/2026
DIED IN
Industries & Professional Activities Subcommittee

Filed under Development & Land Use.

PROVIDED SUMMARY

Temporary Door Locking Devices; Defines "temporary door locking device"; authorizing temporary door locking devices to be installed at any height; requires Florida Building Commission to incorporate certain standards for temporary door locking devices into Florida Building Code; requires use of temporary door locking devices be integrated into building safety plans, safety drills, & training programs for specified purpose.

Full bill text →

Plain English Summary

AI-GENERATED
Allows temporarily locking fire exits and doors during emergencies.

A "temporary door locking device" is defined as hardware that blocks a door from opening, releases from the exit side without a key, requires a key or other credential from the entry side, and cannot alter fire exit hardware, closers, or fire ratings.

The device may be installed at any height on a door, overriding any other law or Building Code provision that would otherwise limit hardware placement, including reach-range rules.

It may also secure a fire exit or the route to one, something ordinary code forbids, but only while an actual emergency or drill is underway and only with sign-off from the local enforcement agency.

The Florida Building Commission must write matching standards into the Building Code, and any building that installs a device must add it to its safety plans, drills, and staff training.

KEY PROVISIONS
§ 1 Requires a key or credential to unlock from the entry side majors. 553.8951(1)(c)

AIThe device must release without a key from the exit side, but removing it from the entry side requires a key or other credential — the mechanism that keeps someone fleeing an emergency from being trapped.

“removed from the ingress side of the door with the use of a key or other credential” bill text, line 26 →
§ 2 Lets a device be installed at any height on a door majors. 553.8951(2)

AIOverrides any other law or Building Code provision that would otherwise limit where hardware sits on a door: a device meeting this definition may be installed at any height above the floor.

“Notwithstanding any other law or provision in the Florida Building Code, a temporary door locking device may be installed at any height” bill text, line 40 →
§ 3 Allows securing a fire exit itself, if approved during an emergency majors. 553.8951(3)

AIA device meeting the definition may be used to lock a fire exit or the path to one — something building and fire code would not otherwise allow — but only while an emergency situation is underway and only once the local enforcement agency with jurisdiction over the building has approved it.

“may be used to secure a fire exit or an entranceway leading to a fire exit” bill text, line 46 →
§ 4 Sets the legal definition of a temporary door locking device moderates. 553.8951(1)

AICreates s. 553.8951 and defines the device by seven criteria: temporary emergency use only, no permanent mount, no change to fire rating or exit hardware, and removable in a single motion.

“a device that prevents a door from opening and meets all of the following criteria” bill text, line 20 →
§ 5 Directs the Building Commission to add matching code standards moderates. 553.8951(3)

AIThe Florida Building Commission must incorporate standards for these devices into the Florida Building Code, turning this section's requirements into an enforceable statewide code provision.

“shall incorporate into the Florida Building Code pursuant to s. 553.73(1) standards for temporary door locking devices” bill text, line 43 →
§ 6 Requires device use in safety plans and staff training moderates. 553.8951(4)

AIAny building that installs one of these devices must incorporate its use into building safety plans, safety drills, and training programs, so employees or staff get inservice training on operating it.

“must be integrated into building safety plans, safety drills, and training programs” bill text, line 56 →
TIMELINE
3/13/2026
Died in Industries & Professional Activities Subcommittee
1/13/2026
1st Reading (Original Filed Version)
12/12/2025
Now in Industries & Professional Activities Subcommittee
12/12/2025
Referred to Commerce Committee
12/12/2025
Referred to State Administration Budget Subcommittee
12/12/2025
Referred to Industries & Professional Activities Subcommittee
11/25/2025
Filed
1 EARLIER →
STATUTES IT CHANGES
s. 553.8951
+380 / −0